IntelliSense FG-1025/1025R Glassbreak Detectors
- Superior False Alarm Immunity
Digital Signal Processing (DSP) uses an on-board microcontroller
with over 1000 lines of software code to instantly digitize
sounds into mathematic sequences, distinguishing common
false alarms from breaking glass.
- Field Proven Glassbreak Protection
As the world's most popular glassbreak detectors,
IntelliSense products are field-proven around the globe
to accurately detect breaking glass.
- Installer-Friendly Installations
Designed with the installer in mind, the detector
features a centered wire entry hole, 45º terminals,
dip switches and optional mounting spacers.
- Mount the Detector Anywhere
Mounts on any wall, in the window frame, or on the ceiling,
with no minimum range and a maximum range of
25' (7.6m) to the glass.
- Fast and Accurate Testing
Place the detector in test mode remotely from the ground
using the hand-held FG-701 Glassbreak Simulator.
- Easily Verify Detector Operation at Any Time
A simple clap of the hands will blink the green LED
verifying the detector is awake and processing incoming sounds.
If at anytime the continuous self test discovers a detector
failure, both the red and the green LEDs will flash.
- Installation Flexibility
The FG-1025 and FG-1025R detect all types of glass with
no loss of range.
Glass Type/Thickness
Minimum size for all glass types is 11" x 11" (28cm x 28 cm)
square; glass must be framed in the wall of the room or mounted
in a barrier of 36" (.9m) minimum width.
| Type |
Min. Thickness |
Max. Thickness |
| Plate |
3/32" (2.4 mm) |
1/4" (6.4 mm) |
| Tempered |
1/8" (3.2 mm) |
1/4" (6.4 mm) |
| Laminated * |
1/8" (3.2 mm) |
9/16" (14.3 mm) |
| Wired |
1/4" (6.4 mm) |
1/4" (6.4 mm) |
| Coated ** |
1/8" (3.2 mm) |
1/4" (6.4 mm) |
| Sealed insulating * |
1/8" (3.2 mm) |
1/4" (3.2 mm) |
FlexGuard® Glassbreak Simulator/Tester
The sound of breaking glass is digitally
simulated by the FG-701.
The FG-701 is compatible for testing all
C&K glassbreak detectors.
C&K highly recommends testing glassbreak
detectors before final installation.
|